FUTEK LTH300 / FSH04815 / FSH00305 | MT-THL-D | Compression, 700 Ω family, WC1. FSH04815 indexed item is 50 lb / 1/4 in nominal; do not infer 3/8 in from the part number.Manufacturer reference ↗ | Request cross-reference → |
FUTEK LTH350 / FSH04599 | MT-THL-D | Smooth compression family with connector variants. Compare actual bore, OD, capacity, connector and drawing revision.Manufacturer reference ↗ | Request cross-reference → |
FUTEK LTH400 / FSH00428 / FSH00442 | MT-THL-D | Smooth compression, not threaded bidirectional. Current family drawing: 50.3 mm OD / 16 mm H, 700 Ω / CC19. Legacy part details require their own drawing.Manufacturer reference ↗ | Request cross-reference → |
FUTEK LTH500 | MT-THL-D / LP | High-capacity compression. Check loading lands, actual bore and capacity; a similar outside envelope does not establish an exact replacement.Manufacturer reference ↗ | Request cross-reference → |
Honeywell Model D | MT-THL-D | Donut compression direction; compare the configured item, actual bore and electrical output.Manufacturer reference ↗ | Request cross-reference → |
Honeywell Model TH / Model 3632 | MT-THL-D / LP | Compression donut/thru-hole review. Low-force thin rings and high-force column designs are separate mechanical cases.Manufacturer reference ↗ | Request cross-reference → |
Honeywell Model 41 | MT-THL-TF | Threaded low-profile tension/compression architecture; verify thread pitch, engagement, flange pattern and loading direction.Manufacturer reference ↗ | Request cross-reference → |
Interface LW / LWHP14 / LWCF | MT-THL-D / B | Washer/clamp-force families. Check each size, rated range, stiffness and cable; no blanket equivalence.Manufacturer reference ↗ | Request cross-reference → |
HBK / HBM KMRplus / KMR+ | MT-THL-B | Installed force-shunt calibration matters. Current KMR+ data includes load-application disks; compare the complete measurement point.Manufacturer reference ↗ | Request cross-reference → |
Kistler 9011A / 9021A / 9031A / 9041A / 9051A / 9061A / 9071A | MT-THL-B | Piezoelectric-to-strain-gauge conversion requires a new conditioner and timing/creep review. It is not an electrical drop-in.Manufacturer reference ↗ | Request cross-reference → |
Transducer Techniques THD | MT-THL-D | THD is a smooth through-hole series calibrated in compression; do not map it to TF solely because the name contains through-hole.Manufacturer reference ↗ | Request cross-reference → |
Stellar Technology Annular / custom reference | MT-THL-LP | Send the exact manufacturer drawing and range. Annular geometry alone does not define a matched part. | Request cross-reference → |
FUTEK instruments USB220 / USB520 / IAA100 / IAA200 / IAC200 | MT-AMP-KIT | Review USB/software, analog ranges, bridge load, number of channels and summed versus independent data. Software and electrical compatibility require confirmation.Manufacturer reference ↗ | Request cross-reference → |